M/E START PRECEDURE
1.CHECK TURNING GEAR NOT ENGAGED
POSITION.
2.CLOSE INDICATOR COCK.
3.STOP M/E C.W PREHEATING.
4.PUT TO STAND-BY POSITION ME L/O STBY
PUMP.
5. PUT TO STAND-BY POSITION RG L/O STBY
PUMP.
6. PUT TO STAND-BY POSITION ME H/T F.W
STBY PUMP.
7.START ONE OF ME L/T F.W PUMP
8. PUT TO STAND-BY POSITION OTHER M.E
L/T F.W PUMP.
9.START ONE OF CPP PUMP.
10.PUT TO AUTO POSITION OTHER CPP PUMP.
11.START ME NOZZLE C.W PUMP.
12.IF NOT, START FUEL CONDITIONING UNIT.
13.PUSH TO “START/STOP” (F2) BUTTON ON
M.E REMOTE CONTROL PANEL.
14.AND THAN PUSH TO (F13) “SOFTKEY 4”
FOR CONFIRM TO STARTING.
15.AND WAIT A FEW MINUTE M.E WILL START.
16.CHECK ALL OF STANDY-BY PUMP WILL STOP
AUTOMATICLY AFTER A FEW SECOND OF M.E START.
17.CHECK REVOLUTION OF M/E, SHOULD BE
STAY AT 450 RPM.
18.PUSH TO “CRPM MODE ON” BUTTON ON CONSOL OF CPP.
19.CHECK RPM WILL RISE TO 750 RPM
20.TURN” ECR” TO “BRIGH” POSITION
SELECTOR SWITCH ON CONSOL OF CPP,WHEN BRIGHT CONFIRME PUSH TO “TAKE OVER
COMMEND” BUTTON.
ANA MAKİNE ÇALIŞTIRMA PROSEDÜRÜ
1.TORNAÇARK’IN TAKILI OLMADIĞINI
KONTROL ET.
2.İNDİKATÖR MUSLUKLARINI KAPAT.
3.ANA MAKİNE CEKET ISITMASINI KAPAT.
4.ANA MAKİNE L/O STBY POMPASINI
STAND-BY KONUMUNA GETİR.
5.RG L/O STBY POMPASINI STAND-BY KONUMUNA GETİRİN.
6.ANA MAKİNE H/T STBY POMPASINI
STAND-BY KONUMUNA GETİR.
7.ANA MAKİNE L/T POMPALRINDAN BİRİNİ
ÇALIŞTIR.
8.DİĞER L/T POMPASINI STAND-BY KONUMUNA
GETİR.
9.CPP POMPALARINDAN BİRİSİNİ MANUEL
OLARAK ÇALIŞTIRIN.
10.DİĞER CPP POMPASINI AUTO KONUMUNA
GETİR.
11.NOZZUL SOĞUTMA SUYU POMPASINI
ÇALIŞTIR.
12.EĞER ÇALIŞMIYOR İSE YAKIT COND.
UNİTESİNİ ÇALIŞTIRIN.
13.ANA MAKİNE KONTROL PANELİ ÜZERİNDEKİ
“STAR/STOP”(F2) TUŞUNA BASIN.
14.ÇALIŞTIRMANIN DOĞRULAMASI İÇİN
“SOFTKEY 4”(F13) TUŞUNA BASIN.
15.BİRKAÇ DAKİKA BEKLEYİNİZ ANA MAKİNE
ÇALIŞACAKTIR.
16.MAKİNENİN ÇALIŞMASINDAN BİRKAÇ SANİYE
SONRA STANDY-BY KONUMUNDA ÇALIŞAN POMPALARIN TÜMÜNÜN OTOMATİK OLARAK STOP ETTİĞİNİ KONTROL EDİN.
17.MAKİNENİN DEVRİNİ KONTROL EDİNİZ ,450
RPM’DE KALMALI.
18.CPP KONTROL PANELİ ÜZERİNDEKİ “CRPM
MODE ON” TUŞUNA BASIN.
19.DEVİRİN750 RPM ‘E ÇIKTIĞINI GÖRÜN.
20. CPP KONTROL PANELİ ÜZERİNDEKİ SEÇİCİ
SİVİCİ “ECR” DEN “BRIGHT” KONUMUNA
ÇEVİRİN,KÖPRÜSTÜ KARŞILADIĞINDA “TAKE OVER COMMAND” TUŞUNA BASIN.
Hiç yorum yok:
Yorum Gönder