- The ordinary
waste oil should be preheated up to about 90 oC. If the waste
oil has an extremely hıgh viscosity it should be preheated up to 110oC.
- During or after
the preheating of the waste oil tank completely discharge drain. It is
recommended to discharge drain as much as possible.
- Set the burner
selector switch (appearing on the control panel) to the auxiliary burner
side.
- When the waste
oil in the waste oil tank is heated in some degree, open the main valve of
the tank to circulate the waste oil in the line.
- Adjust the
combustion air inlet valve regulate the pressure of combustion air. The
standard setting is 0.5 kg/cm2 .
- Set the waste
oil burner running switch (appearing also on the control panel) to off or
circulation.
- With the above
two items finished, depress the run switch, and the cooling fan will
start. When the combustion switch is turned on the auxiliary burner
solenoid pump will start. After 35 seconds of prepurge the fuel line
solenoid valve will be opened by the function of the burner control relay.
- Allow the
auxiliary burner to stand 10 or 15 minutes. In this while, check the
auxiliary burner for abnormalities. When the auxiliary burner is
warrantable and on condition that it is running in order start the waste
oil burner.
- Changeover the
waste oil burner operation from circulation to combustion then the waste
oil solenoid valveis turned on.
- Having confirmed
the waste oil combustion, confirm once more that the secondary oil
pressure is 0.5 kg/cm2
- If there is no
abnormality in the parallel operation of the auxiliary and waste oil
burners, chage over the burner selector switch appearing on the control
panel from auxiliary to waste oil.
- To shut down the
waste oil burner, close the main valve at the waste oil tank and open the
changeover valve at the fuel tank to supply diesel oil to the waste oil
line, untill the entire line from the change over valve to the burner is
filled with diesel oil completely.
- When diesel oil
has been burned out, turn off the waste oil burner running switch, and
depress the incinerators stop button to stop its operation completely.
- For the purpose
of cooling down the combustion chamber keep the cooling fan alone running
for about 30 minutes.